Introduction
This article will walk you through how to use the Master/Slave function on your Rockville Mini RF4 V2 lights. This feature allows one light to control the rest without using a DMX controller, which is ideal for quick setups or synchronized effects. No technical experience is required, and these steps are easy to follow. You’ll just need two or more Mini RF4 V2 lights powered on and within wireless range.
⚠️Please note: This does not allow for remote control, only manual control using Master Light. Remote control setup instructions for multiple Mini RF4 V2 lights can be found in another article, How To Set Up RF Remote Groups.
Master/Slave Setup
A.) Select & Assign the Master Light
Select & Assign the Master Light:
- Choose which light you want to be the Master.
- This light will control all slave lights in the system.
- It is recommended to use the light that will be easiest to control by accessing the buttons / display.
- Activate the light's Master Mode setting.
- Press the Mode button until you see MASTER on or MASTER oFF.
- If you see MASTER oFF, use the Up or Down button to select MASTER on.
- Press the Mode button until you see MASTER on or MASTER oFF.
- Select a Wireless Group ID.
- Press the Mode button until you see 01, 02, 03, 04, 05, 06, 07 or oFF with the corresponding Wireless Group ID color.
- (If necessary) Use the Up or Down button to set the Master's Wireless Group ID # / color.
- Press the Mode button until you see 01, 02, 03, 04, 05, 06, 07 or oFF with the corresponding Wireless Group ID color.
Configure Slave Lights:
- On all Slave Lights...
- Deactivate the light's Master Mode setting:
- Press the Mode button until you see MASTER on or MASTER oFF.
- If you see MASTER on, use the Up or Down button select MASTER oFF.
- Press the Mode button until you see MASTER on or MASTER oFF.
- Select matching Wireless Group ID.
- Press the Mode button until you see 01, 02, 03, 04, 05, 06, 07 or oFF with the corresponding Wireless Group ID color.
- Use the Up or Down button to set matching the Master's Wireless Group ID # / color.
- Press the Mode button until you see 01, 02, 03, 04, 05, 06, 07 or oFF with the corresponding Wireless Group ID color.
- Set to Slave Mode (DMX Address: 001).
- Press the Mode button until you see DMX ADD 001 ~ DMX ADD 512.
- If necessary, use the UP / DOWN buttons to set the address to 001.
- Press the Mode button until you see DMX ADD 001 ~ DMX ADD 512.
- Deactivate the light's Master Mode setting:
-
Once configured...
- Set the Master to any static color, color-changing or sound-active mode. All Mini RF4 V2 lights should respond.
- The Master Light’s Wireless Group ID Icon will stay solid.
- The Slave Lights’ Wireless Group ID Icon will flash, indicating they are synced with the Master Light.
Control the Lights:
- Now that your lights are synced...
- Any changes made on the Master Light will be mirrored on all Slave Lights.
- You can adjust colors, modes, brightness and effects using the Master Light’s buttons.
- For wireless control using the included RF remote, you can check the next section.
Troubleshooting & FAQs
My slave light isn’t syncing. What should I check?
✅Make sure the Wireless ID Group matches exactly on both the master and slave.
✅Make sure the master light has master mode set to on.
✅Make sure the slave light has master mode set to off.
✅Confirm that DMX address/slave mode is activated.
✅Look for the flashing Wireless ID icon on slave light to verify connection.
Can I use more than two lights in this setup?
✅Yes. Just follow the same instructions for each additional light you want to add as a slave.
✅Up to 25 Slave lights can be wirelessly linked to a single Master.
Can I sync my other Rockville lights with my Mini RF4 V2s in Master/Slave Mode
✅Normally Master/Slave Mode only works with lights of the same exact model. However the Rockville Mini IR-series can be linked with the Mini RF4 V2 because they have the same DMX response.
✅No lights of other models or brands can be linked using Master/Slave. You may want to consider using a DMX controller to sync any lights with DMX capabilities.
Conclusion
Using the Master/Slave function on your Rockville Mini RF4 V2 lights is a simple and effective way to synchronize multiple lights for a cohesive vibe. By following the steps above, your lights will stay in sync effortlessly, creating a mesmerizing professional lighting experience.